Champion 100177 Home Standby 8.5KW w/ 10 Circuit Load Center ATS Nema 3R 10yr Warranty

SKU: 100177
Write a Review
MSRP: $3,189.00
Was: $2,999.00
Now: $2,699.10
(You save $489.90 )
FACTORY STOCK | SHIPS 2-3 DAYS
120/240V Single Phase
Adding to cart… The item has been added

Essential Accessories

Click ‘Add to Cart’ to place in cart

Warranty

Manufactures Warranty: 10 Year/2,000-Hour Limited Warranty

Details

FEATURES

  • 8.5kW continuous electrical power
  • 439cc Champion OHV engine, electric start and low oil shut down
  • Automatic 50 amp, 10 circuit outdoor rated Nema 3R transfer switch
  • Champion Auto Control Module (ACM)
  • Generator BASE acts as its own All-weather composite mounting pad
  • All weather steel enclosure
  • Natural gas (NG) or Propane (LPG) operation
  • 10 year limited warranty
  • Reliable
  • 24 volt starting system is the most powerful in the industry.  Designed to assure starting at temperatures as low as -22 degrees F
  • Quietest in class. Comparable to normal conversation.

TRANSFER SWITCH INCLUDED

  • 50 amp Champion Automatic Transfer Switch, NEMA 3R, Outdoor Use 

GENERATOR SPECIFICATIONS

kW (LPG) 8.5
kW (NG) 7.5
LPG Rated Load (A) 70.8/35.4
NG Rated Load (A) 62.5/31.25
Rated Voltage 120/240
Main Line CB (A) 36
Phase 1
Rotor Poles 2
Frequency 60
Insulation Class H
THD (%) <5%
Power Factor 1
Weight (lbs) 365.1 lbs
Dimensions L 49.1" X W28" X H28.3"
Enclosure Material Steel
Enclosure Base Material Composite
Normal Operation Noise Level, Installed 59.5 dBA at 23 ft. (7 m); In front of generator
Operating Range °F(°C) -22°(-30°) to 104°(40°)

ENGINE SPECIFICATIONS

Type: Champion OHV
Displacement (cc) 439
Engine Speed (rpm) 3600
Block Material Alum with Cast Iron Sleeve
Carburetor Type 1-barrel
Governor Type Mechanical
Ignition System Solid State Magneto
Starter 24V
Oil Capacity (qt/L) 1.2/1.1
Oil Cooler No
EPA Certified Yes

FUEL CONSUMPTION

NG Fuel Consumption @ 50% load (m3/hr) 2.76
NG Fuel Consumption @ Full load (m3/hr) 3.96
LPG Fuel Consumption @ 50% load (l/hr) 4.00
LPG Fuel Consumption @ Full load (l/hr) 5.67
Fuel Supply Inlet (NPT) 3/4
* Fuel pressure required for NG 6" w.c.
* Fuel pressure required for LPG 11" w.c.

CONTROL FEATURES

Engine Mode: ATS Automatically starts on utility failure
Engine Mode: Manual Starts unit and runs until turned off
Engine Mode: Off Stops unit / controller and charger active
Transfer Switch Mode: Auto Automatically transfers power on utility failure
Transfer Switch Mode: Off Does not transfer power on utility failure
Transfer Switch Mode: Test Tests all components without starting generator
Generator State Indicator Standard
Programable Start Delay Standard
Weekly Exercise Automatically starts, runs for 15 min
Engine Starting Crank sequence up to five attempts
Starter Lockout Cannot restart for 5 sec after engine stopped
Low Battery Indicator Standard
Battery Charger Fault Indicator Standard
Engine Warm Up 20 sec
Engine Cool Down 1 min
Low Oil Shutdown Standard
Overspeed Shutdown Standard
High Engine Temp Shutdown Standard
Overcrank Protection Standard
Under Speed Protection Standard
Over Speed Protection Standard
Continuous Battery Charging Standard
Hour Meter Standard
Exterior Failed Start Indicator Standard
Utility Voltage Monitor Standard
Safety Fuse Standard
Failure to Transfer Protection Standard
Reverse Polarity Protection Standard

 

Essential Accessories

Click ‘Add to Cart’ to place in cart